BK-AA4530F Atomic Absorption Spectrophotometer
- FOB Price:Get Latest Price >
- Min.Order:1 Set(s)
- Payment Terms:L/C , T/T , PayPal , Money Gram , EXW , FCA
- Favorite
Business Type:Manufacturer
Country/Region:China
Ddu Verified
HOT Rank
6/10
Biobase Biodustry (Shandong) Co., Ltd
We are professional supplier of biological safety cabinet,laminar flow cabinet ,fume hood ,autoclave and sterilizer,laboratory and medical refrigerator and freezer,biochemistry analyzer,IVD reagents,
Business Type:Manufacturer
Country/Region:China
Ddu Verified
HOT Rank
6/10
Features:
* Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
* Integrated floated optical platform design improves the optical system shock resistance stable.
* Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
* Position adjusting: the flame burner can be set on the best position automatically.
* Fully automated wavelength scanning and peak searching.
* Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.
* Deuterium lamp and self-absorption background calibration.
* Measuring method: flame absorption method and emission method.
* Result printing: parameter, data result and diagram.
* Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.
Technical Parameters:
Model | BK-AA4530F |
Wavelength Range | 190~900nm |
Wavelength Accuracy | ±0.15nm |
Wavelength Receptivity | ≤0.04nm |
Base Line Stability | ≤0.002A/30min (Cu) |
Characteristic Concentration | 0.02μg/ml/1% (Cu) |
Detection Limit | 0.004μg/ml (Cu) |
Measurement Repeatability | ≤0.5% |
Grating | 1800 lines/mm |
Inflamer | All-metal titanium burner |
Atomizer | Efficient glass atomizer |
Lamp stand | 8 |
D2 background Calibration | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Power Supply | 220V, 50/60Hz |
Packing Size(mm) | 850*700*750(Main instrument) 950*620*1020(Accessories ) |
Gross Weight(kg) | 105Kg (Main instrument) 100Kg ( Accessories ) |
Standard Accessories | PC workstation HP inkjet printer Oil free Air compressor Acetylene reducing valve Cu Hollow cathode lamp Air filter |
Optional Accessories | Graphite Furnace Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc) |
FLAME SYSTEM
Acetylene Air Burner | 100mm |
Ignition Dynamic Baseline Drift | ≤0.006A/30min |
Characteristic Concentration | ≤0.025μg/ml/1%(Cu) |
Related Standard Deviation of the Accuracy
| ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
Safety System | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner. |
GRAPHITE FURNACE(Optional):
Max. Temperature | 3000℃ |
Max Heating Speed | ≥2000℃/S |
Characteristic Quantity | Cd≤0.5*10-12g Cu≤0.5*10-11g |
Accuracy | Cu≤3% Cd≤3% |
Safety System | Over current protection Low air pressure alarm / protection Low cooling water flow alarm/protection |
Power Supply | 220V, 50Hz |
Consumption | 7000W |
Packing Size(mm) | 550*450*300 |
Gross Weight(kg) | 65 |
Welcome to BIOBASE,I will serve you.